Ver Fonte

ARC: [mm] serious bug in vaddr based icache flush

vaddr used to index the cache was clipped from the wrong end, and thus
would potentially fail to flush the correct lines.

The problem was dorment for so long because up until the recent
optimizations it was only used for ptrace break-point only flushes.

Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
Vineet Gupta há 12 anos atrás
pai
commit
c917a36f5f
1 ficheiros alterados com 1 adições e 1 exclusões
  1. 1 1
      arch/arc/mm/cache_arc700.c

+ 1 - 1
arch/arc/mm/cache_arc700.c

@@ -421,7 +421,7 @@ static void __ic_line_inv_vaddr(unsigned long phy_start, unsigned long vaddr,
 	num_lines = DIV_ROUND_UP(sz, ARC_ICACHE_LINE_LEN);
 
 #if (CONFIG_ARC_MMU_VER > 2)
-	vaddr &= ~ICACHE_LINE_MASK;
+	vaddr &= ICACHE_LINE_MASK;
 	addr = phy_start;
 #else
 	/* bits 17:13 of vaddr go as bits 4:0 of paddr */