소스 검색

ARC: [mm] serious bug in vaddr based icache flush

vaddr used to index the cache was clipped from the wrong end, and thus
would potentially fail to flush the correct lines.

The problem was dorment for so long because up until the recent
optimizations it was only used for ptrace break-point only flushes.

Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
Vineet Gupta 12 년 전
부모
커밋
c917a36f5f
1개의 변경된 파일1개의 추가작업 그리고 1개의 파일을 삭제
  1. 1 1
      arch/arc/mm/cache_arc700.c

+ 1 - 1
arch/arc/mm/cache_arc700.c

@@ -421,7 +421,7 @@ static void __ic_line_inv_vaddr(unsigned long phy_start, unsigned long vaddr,
 	num_lines = DIV_ROUND_UP(sz, ARC_ICACHE_LINE_LEN);
 
 #if (CONFIG_ARC_MMU_VER > 2)
-	vaddr &= ~ICACHE_LINE_MASK;
+	vaddr &= ICACHE_LINE_MASK;
 	addr = phy_start;
 #else
 	/* bits 17:13 of vaddr go as bits 4:0 of paddr */