Преглед на файлове

thermal/cpu_cooling: convert 'switch' block to 'if' block in notifier

We just need to take care of single event here and there is no need to
increase indentation level of most of the code (which causes lines
longer that 80 columns to break).

Kill the switch block.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Viresh Kumar преди 10 години
родител
ревизия
a24af233a1
променени са 1 файла, в които са добавени 10 реда и са изтрити 16 реда
  1. 10 16
      drivers/thermal/cpu_cooling.c

+ 10 - 16
drivers/thermal/cpu_cooling.c

@@ -221,27 +221,21 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
 	unsigned long max_freq;
 	struct cpufreq_cooling_device *cpufreq_dev;
 
-	switch (event) {
+	if (event != CPUFREQ_ADJUST)
+		return NOTIFY_DONE;
 
-	case CPUFREQ_ADJUST:
-		mutex_lock(&cooling_list_lock);
-		list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
-			if (!cpumask_test_cpu(policy->cpu,
-					      &cpufreq_dev->allowed_cpus))
-				continue;
+	mutex_lock(&cooling_list_lock);
+	list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+		if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus))
+			continue;
 
-			max_freq = cpufreq_dev->cpufreq_val;
+		max_freq = cpufreq_dev->cpufreq_val;
 
-			if (policy->max != max_freq)
-				cpufreq_verify_within_limits(policy, 0,
-							     max_freq);
-			break;
-		}
-		mutex_unlock(&cooling_list_lock);
+		if (policy->max != max_freq)
+			cpufreq_verify_within_limits(policy, 0, max_freq);
 		break;
-	default:
-		return NOTIFY_DONE;
 	}
+	mutex_unlock(&cooling_list_lock);
 
 	return NOTIFY_OK;
 }