浏览代码

thermal/cpu_cooling: convert 'switch' block to 'if' block in notifier

We just need to take care of single event here and there is no need to
increase indentation level of most of the code (which causes lines
longer that 80 columns to break).

Kill the switch block.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Viresh Kumar 10 年之前
父节点
当前提交
a24af233a1
共有 1 个文件被更改,包括 10 次插入16 次删除
  1. 10 16
      drivers/thermal/cpu_cooling.c

+ 10 - 16
drivers/thermal/cpu_cooling.c

@@ -221,27 +221,21 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
 	unsigned long max_freq;
 	unsigned long max_freq;
 	struct cpufreq_cooling_device *cpufreq_dev;
 	struct cpufreq_cooling_device *cpufreq_dev;
 
 
-	switch (event) {
+	if (event != CPUFREQ_ADJUST)
+		return NOTIFY_DONE;
 
 
-	case CPUFREQ_ADJUST:
-		mutex_lock(&cooling_list_lock);
-		list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
-			if (!cpumask_test_cpu(policy->cpu,
-					      &cpufreq_dev->allowed_cpus))
-				continue;
+	mutex_lock(&cooling_list_lock);
+	list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+		if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus))
+			continue;
 
 
-			max_freq = cpufreq_dev->cpufreq_val;
+		max_freq = cpufreq_dev->cpufreq_val;
 
 
-			if (policy->max != max_freq)
-				cpufreq_verify_within_limits(policy, 0,
-							     max_freq);
-			break;
-		}
-		mutex_unlock(&cooling_list_lock);
+		if (policy->max != max_freq)
+			cpufreq_verify_within_limits(policy, 0, max_freq);
 		break;
 		break;
-	default:
-		return NOTIFY_DONE;
 	}
 	}
+	mutex_unlock(&cooling_list_lock);
 
 
 	return NOTIFY_OK;
 	return NOTIFY_OK;
 }
 }