瀏覽代碼

clk: tegra: Register the proper number of resets

The number of resets controls is 32 times the number of peripheral
register banks rather than 32 times the number of clocks. This reduces
(drastically) the number of reset controls registered from 10080 (315
clocks * 32) to 224 (6 peripheral register banks * 32).

This also fixes a potential crash because trying to use any of the
excess reset controls (224-10079) would have caused accesses beyond
the array bounds of the peripheral register banks definition array.

Cc: Peter De Schrijver <pdeschrijver@nvidia.com>
Cc: Prashant Gaikwad <pgaikwad@nvidia.com>
Fixes: 6d5b988e7dc5 ("clk: tegra: implement a reset driver")
Cc: stable@vger.kernel.org # 3.14+
Signed-off-by: Thierry Reding <treding@nvidia.com>
Thierry Reding 10 年之前
父節點
當前提交
5e43e25917
共有 1 個文件被更改,包括 1 次插入1 次删除
  1. 1 1
      drivers/clk/tegra/clk.c

+ 1 - 1
drivers/clk/tegra/clk.c

@@ -272,7 +272,7 @@ void __init tegra_add_of_provider(struct device_node *np)
 	of_clk_add_provider(np, of_clk_src_onecell_get, &clk_data);
 
 	rst_ctlr.of_node = np;
-	rst_ctlr.nr_resets = clk_num * 32;
+	rst_ctlr.nr_resets = periph_banks * 32;
 	reset_controller_register(&rst_ctlr);
 }