Browse Source

thermal: kirkwood: Fix valid check for thermal register

The correct value is obtain by first shifting the register by the offset,
later applying the valid mask and finally invert the result.
This check was lacking an extra parenthesis to be strictly correct.

Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Ezequiel Garcia 12 năm trước cách đây
mục cha
commit
02519d3397
1 tập tin đã thay đổi với 2 bổ sung2 xóa
  1. 2 2
      drivers/thermal/kirkwood_thermal.c

+ 2 - 2
drivers/thermal/kirkwood_thermal.c

@@ -41,8 +41,8 @@ static int kirkwood_get_temp(struct thermal_zone_device *thermal,
 	reg = readl_relaxed(priv->sensor);
 
 	/* Valid check */
-	if (!(reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
-	    KIRKWOOD_THERMAL_VALID_MASK) {
+	if (!((reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
+	    KIRKWOOD_THERMAL_VALID_MASK)) {
 		dev_err(&thermal->device,
 			"Temperature sensor reading not valid\n");
 		return -EIO;