thermal: kirkwood: Fix valid check for thermal register

The correct value is obtain by first shifting the register by the offset,
later applying the valid mask and finally invert the result.
This check was lacking an extra parenthesis to be strictly correct.

Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Ezequiel Garcia 12 ani în urmă
părinte
comite
02519d3397
1 a modificat fișierele cu 2 adăugiri și 2 ștergeri
  1. 2 2
      drivers/thermal/kirkwood_thermal.c

+ 2 - 2
drivers/thermal/kirkwood_thermal.c

@@ -41,8 +41,8 @@ static int kirkwood_get_temp(struct thermal_zone_device *thermal,
 	reg = readl_relaxed(priv->sensor);
 
 	/* Valid check */
-	if (!(reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
-	    KIRKWOOD_THERMAL_VALID_MASK) {
+	if (!((reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
+	    KIRKWOOD_THERMAL_VALID_MASK)) {
 		dev_err(&thermal->device,
 			"Temperature sensor reading not valid\n");
 		return -EIO;