Btrfs: put our inode if orphan cleanup fails

When we cross into a different subvol when doing a lookup we will run the orhpan
cleanup.  If this fails however we do not drop the ref to the inode we were
looking up before we return an error, which leads to busy inodes on umount.
Thanks,

Signed-off-by: Josef Bacik <jbacik@fusionio.com>
Josef Bacik 12 năm trước cách đây
mục cha
commit
01cd33674e
1 tập tin đã thay đổi với 3 bổ sung1 xóa
  1. 3 1
      fs/btrfs/inode.c

+ 3 - 1
fs/btrfs/inode.c

@@ -4941,8 +4941,10 @@ struct inode *btrfs_lookup_dentry(struct inode *dir, struct dentry *dentry)
 		if (!(inode->i_sb->s_flags & MS_RDONLY))
 			ret = btrfs_orphan_cleanup(sub_root);
 		up_read(&root->fs_info->cleanup_work_sem);
-		if (ret)
+		if (ret) {
+			iput(inode);
 			inode = ERR_PTR(ret);
+		}
 	}
 
 	return inode;