Эх сурвалжийг харах

Btrfs: put our inode if orphan cleanup fails

When we cross into a different subvol when doing a lookup we will run the orhpan
cleanup.  If this fails however we do not drop the ref to the inode we were
looking up before we return an error, which leads to busy inodes on umount.
Thanks,

Signed-off-by: Josef Bacik <jbacik@fusionio.com>
Josef Bacik 12 жил өмнө
parent
commit
01cd33674e
1 өөрчлөгдсөн 3 нэмэгдсэн , 1 устгасан
  1. 3 1
      fs/btrfs/inode.c

+ 3 - 1
fs/btrfs/inode.c

@@ -4941,8 +4941,10 @@ struct inode *btrfs_lookup_dentry(struct inode *dir, struct dentry *dentry)
 		if (!(inode->i_sb->s_flags & MS_RDONLY))
 			ret = btrfs_orphan_cleanup(sub_root);
 		up_read(&root->fs_info->cleanup_work_sem);
-		if (ret)
+		if (ret) {
+			iput(inode);
 			inode = ERR_PTR(ret);
+		}
 	}
 
 	return inode;