فهرست منبع

Bluetooth: Read flow control mode on AMP controller init

When initializing an AMP controller, read its current flow control
mode so that the correct value is used.

The AMP controller defaults to block based flow control and this
extra command is just to double check.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Marcel Holtmann 12 سال پیش
والد
کامیت
f38ba94147
1فایلهای تغییر یافته به همراه3 افزوده شده و 0 حذف شده
  1. 3 0
      net/bluetooth/hci_core.c

+ 3 - 0
net/bluetooth/hci_core.c

@@ -319,6 +319,9 @@ static void amp_init(struct hci_request *req)
 	/* Read Data Blk size */
 	/* Read Data Blk size */
 	hci_req_add(req, HCI_OP_READ_DATA_BLOCK_SIZE, 0, NULL);
 	hci_req_add(req, HCI_OP_READ_DATA_BLOCK_SIZE, 0, NULL);
 
 
+	/* Read Flow Control Mode */
+	hci_req_add(req, HCI_OP_READ_FLOW_CONTROL_MODE, 0, NULL);
+
 	/* Read Location Data */
 	/* Read Location Data */
 	hci_req_add(req, HCI_OP_READ_LOCATION_DATA, 0, NULL);
 	hci_req_add(req, HCI_OP_READ_LOCATION_DATA, 0, NULL);
 }
 }