瀏覽代碼

ab8500_fg: Don't clear the CCMuxOffset bit

The CCMuxOffset bit is not kept set. This will force the
columb counter of the AB8500 to use the measure offset
calibration. This should increase the accuracy of the fuel
gauge.

Signed-off-by: Kalle Komierowski <karl.komierowski@stericsson.com>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Kalle Komierowski 14 年之前
父節點
當前提交
e32ad07cea
共有 1 個文件被更改,包括 4 次插入4 次删除
  1. 4 4
      drivers/power/ab8500_fg.c

+ 4 - 4
drivers/power/ab8500_fg.c

@@ -484,8 +484,9 @@ static int ab8500_fg_coulomb_counter(struct ab8500_fg *di, bool enable)
 		di->flags.fg_enabled = true;
 	} else {
 		/* Clear any pending read requests */
-		ret = abx500_set_register_interruptible(di->dev,
-			AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG, 0);
+		ret = abx500_mask_and_set_register_interruptible(di->dev,
+			AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG,
+			(RESET_ACCU | READ_REQ), 0);
 		if (ret)
 			goto cc_err;
 
@@ -1403,8 +1404,7 @@ static void ab8500_fg_algorithm_discharging(struct ab8500_fg *di)
 		sleep_time = di->bat->fg_params->init_timer;
 
 		/* Discard the first [x] seconds */
-		if (di->init_cnt >
-			di->bat->fg_params->init_discard_time) {
+		if (di->init_cnt > di->bat->fg_params->init_discard_time) {
 			ab8500_fg_calc_cap_discharge_voltage(di, true);
 
 			ab8500_fg_check_capacity_limits(di, true);