Bladeren bron

hwmon: (lm90) Use generic i2c reads during detection

As indirectly reported by Olof Johansson, the lm90 driver uses a
custom i2c read function even during detection, at which point we
don't know yet what device we're talking with. It would make more
sense to only use the generic i2c read function at this point, so
that we don't log irrelevant errors on misdetection.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
Jean Delvare 18 jaren geleden
bovenliggende
commit
e0ae87a49c
1 gewijzigde bestanden met toevoegingen van 13 en 13 verwijderingen
  1. 13 13
      drivers/hwmon/lm90.c

+ 13 - 13
drivers/hwmon/lm90.c

@@ -531,24 +531,24 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind)
 		kind = lm90;
 
 	if (kind < 0) { /* detection and identification */
-		u8 man_id, chip_id, reg_config1, reg_convrate;
-
-		if (lm90_read_reg(new_client, LM90_REG_R_MAN_ID,
-				  &man_id) < 0
-		 || lm90_read_reg(new_client, LM90_REG_R_CHIP_ID,
-		 		  &chip_id) < 0
-		 || lm90_read_reg(new_client, LM90_REG_R_CONFIG1,
-		 		  &reg_config1) < 0
-		 || lm90_read_reg(new_client, LM90_REG_R_CONVRATE,
-		 		  &reg_convrate) < 0)
+		int man_id, chip_id, reg_config1, reg_convrate;
+
+		if ((man_id = i2c_smbus_read_byte_data(new_client,
+						LM90_REG_R_MAN_ID)) < 0
+		 || (chip_id = i2c_smbus_read_byte_data(new_client,
+						LM90_REG_R_CHIP_ID)) < 0
+		 || (reg_config1 = i2c_smbus_read_byte_data(new_client,
+						LM90_REG_R_CONFIG1)) < 0
+		 || (reg_convrate = i2c_smbus_read_byte_data(new_client,
+						LM90_REG_R_CONVRATE)) < 0)
 			goto exit_free;
 		
 		if ((address == 0x4C || address == 0x4D)
 		 && man_id == 0x01) { /* National Semiconductor */
-			u8 reg_config2;
+			int reg_config2;
 
-			if (lm90_read_reg(new_client, LM90_REG_R_CONFIG2,
-					  &reg_config2) < 0)
+			if ((reg_config2 = i2c_smbus_read_byte_data(new_client,
+						LM90_REG_R_CONFIG2)) < 0)
 				goto exit_free;
 
 			if ((reg_config1 & 0x2A) == 0x00