Pārlūkot izejas kodu

thermal: Bind cooling devices with the correct arguments

When binding cooling devices to thermal zones created from the device
tree the minimum and maximum cooling states are in the wrong order
leading to failure to bind.

Fix the order of cooling states in the call to
thermal_zone_bind_cooling_device to fix this.

Cc:Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Reviewed-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Punit Agrawal 11 gadi atpakaļ
vecāks
revīzija
dd354b84d4
1 mainītis faili ar 2 papildinājumiem un 2 dzēšanām
  1. 2 2
      drivers/thermal/of-thermal.c

+ 2 - 2
drivers/thermal/of-thermal.c

@@ -156,8 +156,8 @@ static int of_thermal_bind(struct thermal_zone_device *thermal,
 
 			ret = thermal_zone_bind_cooling_device(thermal,
 						tbp->trip_id, cdev,
-						tbp->min,
-						tbp->max);
+						tbp->max,
+						tbp->min);
 			if (ret)
 				return ret;
 		}