소스 검색

md/raid5: improve removal of extra devices after reshape.

After a reshape which reduced the number of devices we need
to disconnect the extra devices.
The code for this doesn't currently handle 'replacement' devices.
It is very unlikely that such devices will be present, but it is
safest to handle them anyway.

So simplify the handling.  Just clear In_sync and leave it
to remove_and_add_spaces (which will be called soon) to do
the real works.

Signed-off-by: NeilBrown <neilb@suse.de>
NeilBrown 13 년 전
부모
커밋
da7613b8b0
1개의 변경된 파일5개의 추가작업 그리고 5개의 파일을 삭제
  1. 5 5
      drivers/md/raid5.c

+ 5 - 5
drivers/md/raid5.c

@@ -5755,11 +5755,11 @@ static void raid5_finish_reshape(struct mddev *mddev)
 			     d < conf->raid_disks - mddev->delta_disks;
 			     d++) {
 				struct md_rdev *rdev = conf->disks[d].rdev;
-				if (rdev &&
-				    raid5_remove_disk(mddev, rdev) == 0) {
-					sysfs_unlink_rdev(mddev, rdev);
-					rdev->raid_disk = -1;
-				}
+				if (rdev)
+					clear_bit(In_sync, &rdev->flags);
+				rdev = conf->disks[d].replacement;
+				if (rdev)
+					clear_bit(In_sync, &rdev->flags);
 			}
 		}
 		mddev->layout = conf->algorithm;