소스 검색

Bluetooth: Remove page timeout setting from HCI init sequence

User space should set the page timeout so there's no need to explicitly
set it in the HCI init sequence. Even if user space fails to set it the
controller default value will be used.

Signed-off-by: Johan Hedberg <johan.hedberg@nokia.com>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
Johan Hedberg 15 년 전
부모
커밋
d835060036
1개의 변경된 파일0개의 추가작업 그리고 4개의 파일을 삭제
  1. 0 4
      net/bluetooth/hci_core.c

+ 0 - 4
net/bluetooth/hci_core.c

@@ -254,10 +254,6 @@ static void hci_init_req(struct hci_dev *hdev, unsigned long opt)
 	flt_type = HCI_FLT_CLEAR_ALL;
 	hci_send_cmd(hdev, HCI_OP_SET_EVENT_FLT, 1, &flt_type);
 
-	/* Page timeout ~20 secs */
-	param = cpu_to_le16(0x8000);
-	hci_send_cmd(hdev, HCI_OP_WRITE_PG_TIMEOUT, 2, &param);
-
 	/* Connection accept timeout ~20 secs */
 	param = cpu_to_le16(0x7d00);
 	hci_send_cmd(hdev, HCI_OP_WRITE_CA_TIMEOUT, 2, &param);