瀏覽代碼

NFC: trf7970a: Ensure no more RX data before completing receive

Depending on the interrupt status value given by the
trf7970a, the driver may not know when a receive operation
is complete.  To handle this, the driver waits for a period
of time in case the trf7970a interrupts it again indicating
there are more RX data in the FIFO.  It is possible that the
timeout will occur when there are RX data in the FIFO but
before the trf7970a has generated an interrupt to tell the
driver about it.  Handle this by calling trf7970a_drain_fifo()
(instead of trf7970a_send_upstream() which just passes up the
data gathered to far) to check if there are more data in the
FIFO.  If so, gather that data into the receive buffer.  If
not, pass the data collected so far upstream as before.

Signed-off-by: Mark A. Greer <mgreer@animalcreek.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
Mark A. Greer 11 年之前
父節點
當前提交
afa5b5f13e
共有 1 個文件被更改,包括 1 次插入1 次删除
  1. 1 1
      drivers/nfc/trf7970a.c

+ 1 - 1
drivers/nfc/trf7970a.c

@@ -800,7 +800,7 @@ static void trf7970a_timeout_work_handler(struct work_struct *work)
 	if (trf->ignore_timeout)
 		trf->ignore_timeout = false;
 	else if (trf->state == TRF7970A_ST_WAIT_FOR_RX_DATA_CONT)
-		trf7970a_send_upstream(trf); /* No more rx data so send up */
+		trf7970a_drain_fifo(trf, TRF7970A_IRQ_STATUS_SRX);
 	else if (trf->state == TRF7970A_ST_WAIT_TO_ISSUE_EOF)
 		trf7970a_issue_eof(trf);
 	else