浏览代码

ARM: 7176/1: cpu_pm: register GIC PM notifier only once

When multiple GICs exist on a platform (RealView PB1176/11MP),
we must make sure the PM notifier block is only registered
once, otherwise we end up corrupting the PM notifier list.

The fix is to only register the notifier when initializing
the first GIC, as the power management functions seem
to iterate over all the registered GICs.

Tested on PB11MP and PB1176.

Reported-by: Will Deacon <will.deacon@arm.com>
Tested-by: Will Deacon <will.deacon@arm.com>
Cc: Colin Cross <ccross@android.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Marc Zyngier 14 年之前
父节点
当前提交
abdd7b91da
共有 1 个文件被更改,包括 2 次插入1 次删除
  1. 2 1
      arch/arm/common/gic.c

+ 2 - 1
arch/arm/common/gic.c

@@ -526,7 +526,8 @@ static void __init gic_pm_init(struct gic_chip_data *gic)
 		sizeof(u32));
 	BUG_ON(!gic->saved_ppi_conf);
 
-	cpu_pm_register_notifier(&gic_notifier_block);
+	if (gic == &gic_data[0])
+		cpu_pm_register_notifier(&gic_notifier_block);
 }
 #else
 static void __init gic_pm_init(struct gic_chip_data *gic)