ソースを参照

bnx2x: Use the correct divisor value for PHC clock readings.

Time Sync (PTP) implementation uses the divisor/shift value for converting
the clock ticks to nanoseconds. Driver currently defines shift value as 1,
this results in the nanoseconds value to be calculated as half the actual
value. Hence the user application fails to synchronize the device clock
value with the PTP master device clock. Need to use the 'shift' value of 0.

Signed-off-by: Sony.Chacko <Sony.Chacko@cavium.com>
Signed-off-by: Sudarsana Reddy Kalluru <Sudarsana.Kalluru@cavium.com>
Signed-off-by: Yuval Mintz <Yuval.Mintz@cavium.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Sudarsana Reddy Kalluru 9 年 前
コミット
a6e2846cac
1 ファイル変更1 行追加1 行削除
  1. 1 1
      drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c

+ 1 - 1
drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c

@@ -15241,7 +15241,7 @@ static void bnx2x_init_cyclecounter(struct bnx2x *bp)
 	memset(&bp->cyclecounter, 0, sizeof(bp->cyclecounter));
 	bp->cyclecounter.read = bnx2x_cyclecounter_read;
 	bp->cyclecounter.mask = CYCLECOUNTER_MASK(64);
-	bp->cyclecounter.shift = 1;
+	bp->cyclecounter.shift = 0;
 	bp->cyclecounter.mult = 1;
 }