Bläddra i källkod

PowerCap: Fix mode for energy counter

As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: Dirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Srinivas Pandruvada 12 år sedan
förälder
incheckning
95677a9a38
1 ändrade filer med 6 tillägg och 1 borttagningar
  1. 6 1
      drivers/powercap/powercap_sys.c

+ 6 - 1
drivers/powercap/powercap_sys.c

@@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
 	if (power_zone->ops->get_max_energy_range_uj)
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_max_energy_range_uj.attr;
-	if (power_zone->ops->get_energy_uj)
+	if (power_zone->ops->get_energy_uj) {
+		if (power_zone->ops->reset_energy_uj)
+			dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
+		else
+			dev_attr_energy_uj.attr.mode = S_IRUGO;
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_energy_uj.attr;
+	}
 	if (power_zone->ops->get_power_uw)
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_power_uw.attr;