[media] ds3000: fix LNB supply voltage on Tevii S480 on initialization

The Tevii S480 outputs 18V on startup for the LNB supply voltage and does not
automatically power down. This blocks other receivers connected
to a satellite channel router (EN50494), since the receivers can not send the
required DiSEqC sequences when the Tevii card is connected to a the same SCR.

This patch switches off the LNB supply voltage on initialization of the frontend.

[mchehab@osg.samsung.com: add a comment about why we're explicitly
 turning off voltage at device init]
Cc: stable@vger.kernel.org
Signed-off-by: Ulrich Eckhardt <uli@uli-eckhardt.de>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Ulrich Eckhardt 11 년 전
부모
커밋
8c5bcded11
1개의 변경된 파일7개의 추가작업 그리고 0개의 파일을 삭제
  1. 7 0
      drivers/media/dvb-frontends/ds3000.c

+ 7 - 0
drivers/media/dvb-frontends/ds3000.c

@@ -864,6 +864,13 @@ struct dvb_frontend *ds3000_attach(const struct ds3000_config *config,
 	memcpy(&state->frontend.ops, &ds3000_ops,
 			sizeof(struct dvb_frontend_ops));
 	state->frontend.demodulator_priv = state;
+
+	/*
+	 * Some devices like T480 starts with voltage on. Be sure
+	 * to turn voltage off during init, as this can otherwise
+	 * interfere with Unicable SCR systems.
+	 */
+	ds3000_set_voltage(&state->frontend, SEC_VOLTAGE_OFF);
 	return &state->frontend;
 