With commit 4178bac4f {ARM: call of_clk_init from default time_init handler}, of_clk_init() is always called on machines using default time_init handler. So drop the of_clk_init() from keystone code to avoid below boot errors because of double call. _of_pll_clk_init: error initializing pll mainpllclk _of_pll_clk_init: error initializing pll papllclk _of_pll_clk_init: error initializing pll ddr3apllclk _of_pll_clk_init: error initializing pll ddr3bpllclk _of_pll_clk_init: error initializing pll armpllclk Reported-by: Grygorii Strashko <grygorii.strashko@ti.com> Signed-off-by: Santosh Shilimkar <santosh.shilimkar@ti.com>
@@ -74,7 +74,6 @@ int __init keystone_pm_runtime_init(void)
if (!np)
return 0;
- of_clk_init(NULL);
pm_clk_add_notifier(&platform_bus_type, &platform_domain_notifier);