Просмотр исходного кода

mfd: da9052: Fix register access via SPI

The range of registers used by this driver exceeds that available
via SPI with no paging (127), so we have to override the values
from the default config which is set-up for I2C access.
Also change SPI settings to match device's recommended OTP values.

Signed-off-by: Adam Ward <adam.ward.opensource@diasemi.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Adam Ward 10 лет назад
Родитель
Сommit
72e341c48f
1 измененных файлов с 5 добавлено и 1 удалено
  1. 5 1
      drivers/mfd/da9052-spi.c

+ 5 - 1
drivers/mfd/da9052-spi.c

@@ -32,7 +32,7 @@ static int da9052_spi_probe(struct spi_device *spi)
 	if (!da9052)
 		return -ENOMEM;
 
-	spi->mode = SPI_MODE_0 | SPI_CPOL;
+	spi->mode = SPI_MODE_0;
 	spi->bits_per_word = 8;
 	spi_setup(spi);
 
@@ -43,6 +43,10 @@ static int da9052_spi_probe(struct spi_device *spi)
 
 	config = da9052_regmap_config;
 	config.read_flag_mask = 1;
+	config.reg_bits = 7;
+	config.pad_bits = 1;
+	config.val_bits = 8;
+	config.use_single_rw = 1;
 
 	da9052->regmap = devm_regmap_init_spi(spi, &config);
 	if (IS_ERR(da9052->regmap)) {