Browse Source

iw_cxgb4: don't use WR keys/addrs for 0 byte reads

Only use the read sge lkey/addr and the remote rkey/addr if the
length of the read is not zero. Otherwise the read response might
be treated as the RTR read response and not delivered to the
application. Or worse Terminator hardware will fail a 0B read
if the STAG is 0 even if the read length is 0.

Signed-off-by: Steve Wise <swise@opengridcomputing.com>
Signed-off-by: Ganesh Goudar <ganeshgr@chelsio.com>
Signed-off-by: Doug Ledford <dledford@redhat.com>
Ganesh Goudar 8 năm trước cách đây
mục cha
commit
720336c42e
1 tập tin đã thay đổi với 1 bổ sung1 xóa
  1. 1 1
      drivers/infiniband/hw/cxgb4/qp.c

+ 1 - 1
drivers/infiniband/hw/cxgb4/qp.c

@@ -569,7 +569,7 @@ static int build_rdma_read(union t4_wr *wqe, struct ib_send_wr *wr, u8 *len16)
 {
 	if (wr->num_sge > 1)
 		return -EINVAL;
-	if (wr->num_sge) {
+	if (wr->num_sge && wr->sg_list[0].length) {
 		wqe->read.stag_src = cpu_to_be32(rdma_wr(wr)->rkey);
 		wqe->read.to_src_hi = cpu_to_be32((u32)(rdma_wr(wr)->remote_addr
 							>> 32));