Browse Source

clocksource: sunxi: Stop timer from ticking before enabling interrupts

The sun4i timer can still be ticking when we enable the interrupt.
If another timer is actually used (A7 architected timer, for example),
odds are that the interrupt will eventually fire with the event_handler
pointer being NULL.

The obvious fix it to stop the timer before registering the interrupt.

Observed and tested on sun7i (cubietruck).

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Marc Zyngier 12 năm trước cách đây
mục cha
commit
6db50bb675
1 tập tin đã thay đổi với 3 bổ sung0 xóa
  1. 3 0
      drivers/clocksource/sun4i_timer.c

+ 3 - 0
drivers/clocksource/sun4i_timer.c

@@ -179,6 +179,9 @@ static void __init sun4i_timer_init(struct device_node *node)
 	writel(TIMER_CTL_CLK_SRC(TIMER_CTL_CLK_SRC_OSC24M),
 	       timer_base + TIMER_CTL_REG(0));
 
+	/* Make sure timer is stopped before playing with interrupts */
+	sun4i_clkevt_time_stop(0);
+
 	ret = setup_irq(irq, &sun4i_timer_irq);
 	if (ret)
 		pr_warn("failed to setup irq %d\n", irq);