Bladeren bron

thermal: Fix polling frequency for systems without passive cooling

The polling interval (in deciseconds) was accidently interpreted as
being in milliseconds in one codepath, resulting in excessively frequent
polling. Ensure that the conversion is performed.

Signed-off-by: Matthew Garrett <mjg@redhat.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
Matthew Garrett 16 jaren geleden
bovenliggende
commit
67405439bc
1 gewijzigde bestanden met toevoegingen van 1 en 1 verwijderingen
  1. 1 1
      drivers/acpi/thermal.c

+ 1 - 1
drivers/acpi/thermal.c

@@ -909,7 +909,7 @@ static int acpi_thermal_register_thermal_zone(struct acpi_thermal *tz)
 			thermal_zone_device_register("acpitz", trips, tz,
 						     &acpi_thermal_zone_ops,
 						     0, 0, 0,
-						     tz->polling_frequency);
+						     tz->polling_frequency*100);
 	if (IS_ERR(tz->thermal_zone))
 		return -ENODEV;