Browse Source

power: supply: sbs-battery: use correct flags field

commit 99956a9e08251a1234434b492875b1eaff502a12 upstream.

the type flag is stored in the chip->flags field not in the
client->flags field. This currently leads to never using the ti
specific health function as client->flags doesn't use that bit.
So it's always falling back to the general one.

Fixes: 76b16f4cdfb8 ("power: supply: sbs-battery: don't assume MANUFACTURER_DATA formats")
Cc: <stable@vger.kernel.org>
Signed-off-by: Michael Nosthoff <committed@heine.so>
Reviewed-by: Brian Norris <briannorris@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Michael Nosthoff 6 years ago
parent
commit
5cb6dd8231
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/power/supply/sbs-battery.c

+ 1 - 1
drivers/power/supply/sbs-battery.c

@@ -629,7 +629,7 @@ static int sbs_get_property(struct power_supply *psy,
 	switch (psp) {
 	case POWER_SUPPLY_PROP_PRESENT:
 	case POWER_SUPPLY_PROP_HEALTH:
-		if (client->flags & SBS_FLAGS_TI_BQ20Z75)
+		if (chip->flags & SBS_FLAGS_TI_BQ20Z75)
 			ret = sbs_get_ti_battery_presence_and_health(client,
 								     psp, val);
 		else