瀏覽代碼

e1000e: prevent division by zero if TIMINCA is zero

Users report that under VMWare, er32(TIMINCA) returns zero.
This causes division by zero at init time as follows:

 ==>       incvalue = er32(TIMINCA) & E1000_TIMINCA_INCVALUE_MASK;
           for (i = 0; i < E1000_MAX_82574_SYSTIM_REREADS; i++) {
                   /* latch SYSTIMH on read of SYSTIML */
                   systim_next = (cycle_t)er32(SYSTIML);
                   systim_next |= (cycle_t)er32(SYSTIMH) << 32;

                   time_delta = systim_next - systim;
                   temp = time_delta;
 ====>             rem = do_div(temp, incvalue);

This change makes kernel survive this, and users report that
NIC does work after this change.

Since on real hardware incvalue is never zero, this should not affect
real hardware use case.

Signed-off-by: Denys Vlasenko <dvlasenk@redhat.com>
Tested-by: Aaron Brown <aaron.f.brown@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Denys Vlasenko 9 年之前
父節點
當前提交
3d05b15b03
共有 1 個文件被更改,包括 2 次插入1 次删除
  1. 2 1
      drivers/net/ethernet/intel/e1000e/netdev.c

+ 2 - 1
drivers/net/ethernet/intel/e1000e/netdev.c

@@ -4352,7 +4352,8 @@ static cycle_t e1000e_cyclecounter_read(const struct cyclecounter *cc)
 
 			time_delta = systim_next - systim;
 			temp = time_delta;
-			rem = do_div(temp, incvalue);
+			/* VMWare users have seen incvalue of zero, don't div / 0 */
+			rem = incvalue ? do_div(temp, incvalue) : (time_delta != 0);
 
 			systim = systim_next;