瀏覽代碼

md/raid5: Mark device want_replacement when we see a write error.

Now that WantReplacement drives are replaced cleanly, mark a drive
as WantReplacement when we see a write error.  It might get failed soon so
the WantReplacement flag is irrelevant, but if the write error is recorded
in the bad block log, we still want to activate any spare that might
be available.

Reviewed-by: Dan Williams <dan.j.williams@intel.com>
Signed-off-by:  NeilBrown <neilb@suse.de>
NeilBrown 14 年之前
父節點
當前提交
3a6de2924a
共有 1 個文件被更改,包括 3 次插入0 次删除
  1. 3 0
      drivers/md/raid5.c

+ 3 - 0
drivers/md/raid5.c

@@ -1796,6 +1796,9 @@ static void raid5_end_write_request(struct bio *bi, int error)
 		if (!uptodate) {
 			set_bit(WriteErrorSeen, &rdev->flags);
 			set_bit(R5_WriteError, &sh->dev[i].flags);
+			if (!test_and_set_bit(WantReplacement, &rdev->flags))
+				set_bit(MD_RECOVERY_NEEDED,
+					&rdev->mddev->recovery);
 		} else if (is_badblock(rdev, sh->sector,
 				       STRIPE_SECTORS,
 				       &first_bad, &bad_sectors))