Selaa lähdekoodia

sx8: use real time for the command seconds

Commit 8182503df1ba used monotonic time, but if the adapter is
using the seconds for logging entries, then we'll get duplicate
entries if the system is rebooted. Use real time instead.

Reported-by: Arnd Bergmann <arnd@arndb.de>
Fixes: 8182503df1ba ("block: sx8.c: Replace timeval with ktime_t")
Signed-off-by: Jens Axboe <axboe@fb.com>
Jens Axboe 10 vuotta sitten
vanhempi
commit
39fc8830eb
1 muutettua tiedostoa jossa 1 lisäystä ja 1 poistoa
  1. 1 1
      drivers/block/sx8.c

+ 1 - 1
drivers/block/sx8.c

@@ -673,7 +673,7 @@ static unsigned int carm_fill_sync_time(struct carm_host *host,
 {
 {
 	struct carm_msg_sync_time *st = mem;
 	struct carm_msg_sync_time *st = mem;
 
 
-	time64_t tv = ktime_get_seconds();
+	time64_t tv = ktime_get_real_seconds();
 
 
 	memset(st, 0, sizeof(*st));
 	memset(st, 0, sizeof(*st));
 	st->type	= CARM_MSG_MISC;
 	st->type	= CARM_MSG_MISC;