@@ -0,0 +1,84 @@
|
|
|
+NXP LPC1850 Reset Generation Unit (RGU)
|
|
|
+========================================
|
|
|
+
|
|
|
+Please also refer to reset.txt in this directory for common reset
|
|
|
+controller binding usage.
|
|
|
+
|
|
|
+Required properties:
|
|
|
+- compatible: Should be "nxp,lpc1850-rgu"
|
|
|
+- reg: register base and length
|
|
|
+- clocks: phandle and clock specifier to RGU clocks
|
|
|
+- clock-names: should contain "delay" and "reg"
|
|
|
+- #reset-cells: should be 1
|
|
|
+
|
|
|
+See table below for valid peripheral reset numbers. Numbers not
|
|
|
+in the table below are either reserved or not applicable for
|
|
|
+normal operation.
|
|
|
+
|
|
|
+Reset Peripheral
|
|
|
+ 9 System control unit (SCU)
|
|
|
+ 12 ARM Cortex-M0 subsystem core (LPC43xx only)
|
|
|
+ 13 CPU core
|
|
|
+ 16 LCD controller
|
|
|
+ 17 USB0
|
|
|
+ 18 USB1
|
|
|
+ 19 DMA
|
|
|
+ 20 SDIO
|
|
|
+ 21 External memory controller (EMC)
|
|
|
+ 22 Ethernet
|
|
|
+ 25 Flash bank A
|
|
|
+ 27 EEPROM
|
|
|
+ 28 GPIO
|
|
|
+ 29 Flash bank B
|
|
|
+ 32 Timer0
|
|
|
+ 33 Timer1
|
|
|
+ 34 Timer2
|
|
|
+ 35 Timer3
|
|
|
+ 36 Repetitive Interrupt timer (RIT)
|
|
|
+ 37 State Configurable Timer (SCT)
|
|
|
+ 38 Motor control PWM (MCPWM)
|
|
|
+ 39 QEI
|
|
|
+ 40 ADC0
|
|
|
+ 41 ADC1
|
|
|
+ 42 DAC
|
|
|
+ 44 USART0
|
|
|
+ 45 UART1
|
|
|
+ 46 USART2
|
|
|
+ 47 USART3
|
|
|
+ 48 I2C0
|
|
|
+ 49 I2C1
|
|
|
+ 50 SSP0
|
|
|
+ 51 SSP1
|
|
|
+ 52 I2S0 and I2S1
|
|
|
+ 53 Serial Flash Interface (SPIFI)
|
|
|
+ 54 C_CAN1
|
|
|
+ 55 C_CAN0
|
|
|
+ 56 ARM Cortex-M0 application core (LPC4370 only)
|
|
|
+ 57 SGPIO (LPC43xx only)
|
|
|
+ 58 SPI (LPC43xx only)
|
|
|
+ 60 ADCHS (12-bit ADC) (LPC4370 only)
|
|
|
+
|
|
|
+Refer to NXP LPC18xx or LPC43xx user manual for more details about
|
|
|
+the reset signals and the connected block/peripheral.
|
|
|
+
|
|
|
+Reset provider example:
|
|
|
+rgu: reset-controller@40053000 {
|
|
|
+ compatible = "nxp,lpc1850-rgu";
|
|
|
+ reg = <0x40053000 0x1000>;
|
|
|
+ clocks = <&cgu BASE_SAFE_CLK>, <&ccu1 CLK_CPU_BUS>;
|
|
|
+ clock-names = "delay", "reg";
|
|
|
+ #reset-cells = <1>;
|
|
|
+};
|
|
|
+
|
|
|
+Reset consumer example:
|
|
|
+mac: ethernet@40010000 {
|
|
|
+ compatible = "nxp,lpc1850-dwmac", "snps,dwmac-3.611", "snps,dwmac";
|
|
|
+ reg = <0x40010000 0x2000>;
|
|
|
+ interrupts = <5>;
|
|
|
+ interrupt-names = "macirq";
|
|
|
+ clocks = <&ccu1 CLK_CPU_ETHERNET>;
|
|
|
+ clock-names = "stmmaceth";
|
|
|
+ resets = <&rgu 22>;
|
|
|
+ reset-names = "stmmaceth";
|
|
|
+ status = "disabled";
|
|
|
+};
|