ceph: let MDS adjust readdir 'frag'

If readdir 'frag' is adjusted, readdir 'offset' should be reset.
Otherwise some dentries may be lost when readdir and fragmenting
directory happen at the some.

Another way to fix this issue is let MDS adjust readdir 'frag'.
The code that handles MDS reply reset the readdir 'offset' if
the readdir reply is different than the requested one.

Signed-off-by: Yan, Zheng <zheng.z.yan@intel.com>
Yan, Zheng 12 лет назад
Родитель
Сommit
15289dc85b
1 измененных файлов с 0 добавлено и 3 удалено
  1. 0 3
      fs/ceph/dir.c

+ 0 - 3
fs/ceph/dir.c

@@ -322,9 +322,6 @@ more:
 			fi->last_readdir = NULL;
 		}
 
-		/* requery frag tree, as the frag topology may have changed */
-		frag = ceph_choose_frag(ceph_inode(inode), frag, NULL, NULL);
-
 		dout("readdir fetching %llx.%llx frag %x offset '%s'\n",
 		     ceph_vinop(inode), frag, fi->last_name);