Explorar o código

iio: humidity: hdc100x: fix IIO_TEMP channel reporting

IIO_TEMP channel was being incorrectly reported back as Celsius when it
should have been milliCelsius. This is via an incorrect scale value being
returned to userspace.

Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Matt Ranostay %!s(int64=9) %!d(string=hai) anos
pai
achega
09bc0ddaab
Modificáronse 1 ficheiros con 1 adicións e 1 borrados
  1. 1 1
      drivers/iio/humidity/hdc100x.c

+ 1 - 1
drivers/iio/humidity/hdc100x.c

@@ -211,7 +211,7 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,
 		return IIO_VAL_INT_PLUS_MICRO;
 	case IIO_CHAN_INFO_SCALE:
 		if (chan->type == IIO_TEMP) {
-			*val = 165;
+			*val = 165000;
 			*val2 = 65536 >> 2;
 			return IIO_VAL_FRACTIONAL;
 		} else {