소스 검색

media: adv7511: fix incorrect clear of CEC receive interrupt

If a CEC message was received and the RX interrupt was set, but
not yet processed, and a new transmit was issues, then the
transmit code would inadvertently clear the RX interrupt and
after that no new messages would ever be received.

Instead it should only clear TX interrupts since register 0x97
is a clear-on-write register.

Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Hans Verkuil 7 년 전
부모
커밋
00f6f92dbb
1개의 변경된 파일2개의 추가작업 그리고 2개의 파일을 삭제
  1. 2 2
      drivers/media/i2c/adv7511.c

+ 2 - 2
drivers/media/i2c/adv7511.c

@@ -831,8 +831,8 @@ static int adv7511_cec_adap_transmit(struct cec_adapter *adap, u8 attempts,
 	 */
 	adv7511_cec_write_and_or(sd, 0x12, ~0x70, max(1, attempts - 1) << 4);
 
-	/* blocking, clear cec tx irq status */
-	adv7511_wr_and_or(sd, 0x97, 0xc7, 0x38);
+	/* clear cec tx irq status */
+	adv7511_wr(sd, 0x97, 0x38);
 
 	/* write data */
 	for (i = 0; i < len; i++)