Thomas Gleixner 8c56e7214e [PATCH] irq-flags: PARISC: Use the new IRQF_ constants пре 19 година
..
Kconfig 8ffaeaf42e [PARISC] PDC_CHASSIS is implemented on all machines пре 19 година
Makefile 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
README.dino 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
asp.c 53f01bba49 [PARISC] Convert parisc_device to use struct resource for hpa пре 20 година
ccio-dma.c 6ab3d5624e Remove obsolete #include <linux/config.h> пре 19 година
ccio-rm-dma.c 53f01bba49 [PARISC] Convert parisc_device to use struct resource for hpa пре 20 година
dino.c 6ab3d5624e Remove obsolete #include <linux/config.h> пре 19 година
eisa.c 8c56e7214e [PATCH] irq-flags: PARISC: Use the new IRQF_ constants пре 19 година
eisa_eeprom.c 45dbe9147d [PARISC] Add __user annotation to eisa_eeprom.c пре 20 година
eisa_enumerator.c 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
gsc.c 6ab3d5624e Remove obsolete #include <linux/config.h> пре 19 година
gsc.h 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
hppb.c cb6fc18e9c [PARISC] Use kzalloc and other janitor-style cleanups пре 20 година
iommu-helpers.h 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
iosapic.c d1bef4ed5f [PATCH] genirq: rename desc->handler to desc->chip пре 19 година
iosapic_private.h 1da177e4c3 Linux-2.6.12-rc2 пре 21 година
lasi.c 85509c0007 [PARISC] Add chassis_power_off routine пре 20 година
lba_pci.c 5076c15862 [PARISC] I/O-Space must be ioremap_nocache()'d пре 20 година
led.c 22a3e233ca Merge git://git.kernel.org/pub/scm/linux/kernel/git/bunk/trivial пре 19 година
pdc_stable.c 67a061a191 [PARISC] Add os_id_to_string helper пре 19 година
power.c 6ab3d5624e Remove obsolete #include <linux/config.h> пре 19 година
sba_iommu.c 6ab3d5624e Remove obsolete #include <linux/config.h> пре 19 година
superio.c 8c56e7214e [PATCH] irq-flags: PARISC: Use the new IRQF_ constants пре 19 година
wax.c cb6fc18e9c [PARISC] Use kzalloc and other janitor-style cleanups пре 20 година

README.dino

/*
** HP VISUALIZE Workstation PCI Bus Defect
**
** "HP has discovered a potential system defect that can affect
** the behavior of five models of HP VISUALIZE workstations when
** equipped with third-party or customer-installed PCI I/O expansion
** cards. The defect is limited to the HP C180, C160, C160L, B160L,
** and B132L VISUALIZE workstations, and will only be encountered
** when data is transmitted through PCI I/O expansion cards on the
** PCI bus. HP-supplied graphics cards that utilize the PCI bus are
** not affected."
**
** REVISIT: "go/pci_defect" link below is stale.
** HP Internal can use
**
** Product First Good Serial Number
** C200/C240 (US) US67350000
**B132L+/B180 (US) US67390000
** C200 (Europe) 3713G01000
** B180L (Europe) 3720G01000
**
** Note that many boards were fixed/replaced under a free replacement
** program. Assume a machine is only "suspect" until proven otherwise.
**
** "The pci_check program will also be available as application
** patch PHSS_12295"
*/