瀏覽代碼

staging: winbond: Change variable type to bool

The variable Trigger is only assigned the values true and false.
Change its type to bool.

The simplified semantic patch that find this problem is as
follows (http://coccinelle.lip6.fr/):

@exists@
type T;
identifier b;
@@
- T
+ bool
  b = ...;
  ... when any
  b = \(true\|false\)

Signed-off-by: Peter Senna Tschudin <peter.senna@gmail.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Peter Senna Tschudin 12 年之前
父節點
當前提交
ffb324aa16
共有 1 個文件被更改,包括 1 次插入1 次删除
  1. 1 1
      drivers/staging/winbond/wb35tx.c

+ 1 - 1
drivers/staging/winbond/wb35tx.c

@@ -180,7 +180,7 @@ void Wb35Tx_CurrentTime(struct wbsoft_priv *adapter, u32 TimeCount)
 {
 	struct hw_data *pHwData = &adapter->sHwData;
 	struct wb35_tx *pWb35Tx = &pHwData->Wb35Tx;
-	unsigned char Trigger = false;
+	bool Trigger = false;
 
 	if (pWb35Tx->TxTimer > TimeCount)
 		Trigger = true;