@@ -401,12 +401,31 @@ get/set up to 64 properties. The actual meaning of each property is described on
|
|
|
the polarzation (horizontal/vertical). When using DiSEqC epuipment this
|
|
|
voltage has to be switched consistently to the DiSEqC commands as
|
|
|
described in the DiSEqC spec.</para>
|
|
|
- <programlisting>
|
|
|
- typedef enum fe_sec_voltage {
|
|
|
- SEC_VOLTAGE_13,
|
|
|
- SEC_VOLTAGE_18
|
|
|
- } fe_sec_voltage_t;
|
|
|
- </programlisting>
|
|
|
+
|
|
|
+<table pgwide="1" frame="none" id="fe-sec-voltage">
|
|
|
+ <title id="fe-sec-voltage-t">enum fe_sec_voltage</title>
|
|
|
+ <tgroup cols="2">
|
|
|
+ &cs-def;
|
|
|
+ <thead>
|
|
|
+ <row>
|
|
|
+ <entry>ID</entry>
|
|
|
+ <entry>Description</entry>
|
|
|
+ </row>
|
|
|
+ </thead>
|
|
|
+ <tbody valign="top">
|
|
|
+ <row>
|
|
|
+ <entry align="char" id="SEC-VOLTAGE-13"><constant>SEC_VOLTAGE_13</constant></entry>
|
|
|
+ <entry align="char">Set DC voltage level to 13V</entry>
|
|
|
+ </row><row>
|
|
|
+ <entry align="char" id="SEC-VOLTAGE-18"><constant>SEC_VOLTAGE_18</constant></entry>
|
|
|
+ <entry align="char">Set DC voltage level to 18V</entry>
|
|
|
+ </row><row>
|
|
|
+ <entry align="char" id="SEC-VOLTAGE-OFF"><constant>SEC_VOLTAGE_OFF</constant></entry>
|
|
|
+ <entry align="char">Don't send any voltage to the antenna</entry>
|
|
|
+ </row>
|
|
|
+ </tbody>
|
|
|
+ </tgroup>
|
|
|
+</table>
|
|
|
</section>
|
|
|
<section id="DTV-TONE">
|
|
|
<title><constant>DTV_TONE</constant></title>
|