Ver código fonte

hwmon: (scpi) add energy meter support

SCPI specification v1.1 adds support for energy sensors. This patch
adds support for the same.

Acked-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
Sudeep Holla 9 anos atrás
pai
commit
fb3b07ef39
2 arquivos alterados com 9 adições e 0 exclusões
  1. 8 0
      drivers/hwmon/scpi-hwmon.c
  2. 1 0
      include/linux/scpi_protocol.h

+ 8 - 0
drivers/hwmon/scpi-hwmon.c

@@ -114,6 +114,7 @@ static int scpi_hwmon_probe(struct platform_device *pdev)
 {
 	u16 nr_sensors, i;
 	int num_temp = 0, num_volt = 0, num_current = 0, num_power = 0;
+	int num_energy = 0;
 	struct scpi_ops *scpi_ops;
 	struct device *hwdev, *dev = &pdev->dev;
 	struct scpi_sensors *scpi_sensors;
@@ -182,6 +183,13 @@ static int scpi_hwmon_probe(struct platform_device *pdev)
 				 "power%d_label", num_power + 1);
 			num_power++;
 			break;
+		case ENERGY:
+			snprintf(sensor->input, sizeof(sensor->input),
+				 "energy%d_input", num_energy + 1);
+			snprintf(sensor->label, sizeof(sensor->input),
+				 "energy%d_label", num_energy + 1);
+			num_energy++;
+			break;
 		default:
 			continue;
 		}

+ 1 - 0
include/linux/scpi_protocol.h

@@ -33,6 +33,7 @@ enum scpi_sensor_class {
 	VOLTAGE,
 	CURRENT,
 	POWER,
+	ENERGY,
 };
 
 struct scpi_sensor_info {