Преглед изворни кода

libnvdimm, testing: update the default smart ctrl_temperature

The default value for smart ctrl_temperature was the same as the
threshold for ctrl_temperature. As a result, any arbitrary smart
injection to the nfit_test dimm could cause this alarm to trigger
and cause an acpi notification. Drop the default value to below the
threshold, so that unrelated injections don't trigger notifications.

Cc: Dan Williams <dan.j.williams@intel.com>
Signed-off-by: Vishal Verma <vishal.l.verma@intel.com>
Signed-off-by: Dan Williams <dan.j.williams@intel.com>
Vishal Verma пре 7 година
родитељ
комит
f6adcca02c
1 измењених фајлова са 1 додато и 1 уклоњено
  1. 1 1
      tools/testing/nvdimm/test/nfit.c

+ 1 - 1
tools/testing/nvdimm/test/nfit.c

@@ -1259,7 +1259,7 @@ static void smart_init(struct nfit_test *t)
 			| ND_INTEL_SMART_MTEMP_VALID,
 		.health = ND_INTEL_SMART_NON_CRITICAL_HEALTH,
 		.media_temperature = 23 * 16,
-		.ctrl_temperature = 30 * 16,
+		.ctrl_temperature = 25 * 16,
 		.pmic_temperature = 40 * 16,
 		.spares = 75,
 		.alarm_flags = ND_INTEL_SMART_SPARE_TRIP