소스 검색

Bluetooth: Read flow control mode on AMP controller init

When initializing an AMP controller, read its current flow control
mode so that the correct value is used.

The AMP controller defaults to block based flow control and this
extra command is just to double check.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Marcel Holtmann 12 년 전
부모
커밋
f38ba94147
1개의 변경된 파일3개의 추가작업 그리고 0개의 파일을 삭제
  1. 3 0
      net/bluetooth/hci_core.c

+ 3 - 0
net/bluetooth/hci_core.c

@@ -319,6 +319,9 @@ static void amp_init(struct hci_request *req)
 	/* Read Data Blk size */
 	hci_req_add(req, HCI_OP_READ_DATA_BLOCK_SIZE, 0, NULL);
 
+	/* Read Flow Control Mode */
+	hci_req_add(req, HCI_OP_READ_FLOW_CONTROL_MODE, 0, NULL);
+
 	/* Read Location Data */
 	hci_req_add(req, HCI_OP_READ_LOCATION_DATA, 0, NULL);
 }