@@ -0,0 +1,21 @@
|
|
|
+NXP LPC1850 ADC bindings
|
|
|
+
|
|
|
+Required properties:
|
|
|
+- compatible: Should be "nxp,lpc1850-adc"
|
|
|
+- reg: Offset and length of the register set for the ADC device
|
|
|
+- interrupts: The interrupt number for the ADC device
|
|
|
+- clocks: The root clock of the ADC controller
|
|
|
+- vref-supply: The regulator supply ADC reference voltage
|
|
|
+- resets: phandle to reset controller and line specifier
|
|
|
+
|
|
|
+Example:
|
|
|
+
|
|
|
+adc0: adc@400e3000 {
|
|
|
+ compatible = "nxp,lpc1850-adc";
|
|
|
+ reg = <0x400e3000 0x1000>;
|
|
|
+ interrupts = <17>;
|
|
|
+ clocks = <&ccu1 CLK_APB3_ADC0>;
|
|
|
+ vref-supply = <®_vdda>;
|
|
|
+ resets = <&rgu 40>;
|
|
|
+ status = "disabled";
|
|
|
+};
|