mtd: nand: sunxi: let the NAND controller control the CE line

We don't need to manually toggle the CE line since the controller handles
it for us. Moreover, keeping the CE line low when interacting with a DDR
NAND can be problematic (data loss in some corner cases).

Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Boris Brezillon 9 年之前
父节点
当前提交
ece03cfd52
共有 1 个文件被更改,包括 0 次插入10 次删除
  1. 0 10
      drivers/mtd/nand/sunxi_nand.c

+ 0 - 10
drivers/mtd/nand/sunxi_nand.c

@@ -514,21 +514,11 @@ static void sunxi_nfc_cmd_ctrl(struct mtd_info *mtd, int dat,
 	struct sunxi_nand_chip *sunxi_nand = to_sunxi_nand(nand);
 	struct sunxi_nfc *nfc = to_sunxi_nfc(sunxi_nand->nand.controller);
 	int ret;
-	u32 tmp;
 
 	ret = sunxi_nfc_wait_cmd_fifo_empty(nfc);
 	if (ret)
 		return;
 
-	if (ctrl & NAND_CTRL_CHANGE) {
-		tmp = readl(nfc->regs + NFC_REG_CTL);
-		if (ctrl & NAND_NCE)
-			tmp |= NFC_CE_CTL;
-		else
-			tmp &= ~NFC_CE_CTL;
-		writel(tmp, nfc->regs + NFC_REG_CTL);
-	}
-
 	if (dat == NAND_CMD_NONE && (ctrl & NAND_NCE) &&
 	    !(ctrl & (NAND_CLE | NAND_ALE))) {
 		u32 cmd = 0;