浏览代码

i2c: at91: Read all available bytes at once

With FIFO enabled it is possible to read multiple bytes
at once in the interrupt handler as long as RXRDY is
set. This may also reduce the number of interrupts.

This patch polls RXRDY and reads all available bytes at
once.

Signed-off-by: David Engraf <david.engraf@sysgo.com>
Acked-by: Ludovic Desroches <ludovic.desroches@microchip.com>
[wsa: reformatted comment]
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
David Engraf 7 年之前
父节点
当前提交
e8f39e9fc0
共有 1 个文件被更改,包括 10 次插入2 次删除
  1. 10 2
      drivers/i2c/busses/i2c-at91.c

+ 10 - 2
drivers/i2c/busses/i2c-at91.c

@@ -518,8 +518,16 @@ static irqreturn_t atmel_twi_interrupt(int irq, void *dev_id)
 	 * the RXRDY interrupt first in order to not keep garbage data in the
 	 * Receive Holding Register for the next transfer.
 	 */
-	if (irqstatus & AT91_TWI_RXRDY)
-		at91_twi_read_next_byte(dev);
+	if (irqstatus & AT91_TWI_RXRDY) {
+		/*
+		 * Read all available bytes at once by polling RXRDY usable w/
+		 * and w/o FIFO. With FIFO enabled we could also read RXFL and
+		 * avoid polling RXRDY.
+		 */
+		do {
+			at91_twi_read_next_byte(dev);
+		} while (at91_twi_read(dev, AT91_TWI_SR) & AT91_TWI_RXRDY);
+	}
 
 	/*
 	 * When a NACK condition is detected, the I2C controller sets the NACK,