@@ -2685,7 +2685,7 @@ static int polaris10_get_evv_voltages(struct pp_hwmgr *hwmgr)
|
|
|
{
|
|
|
struct polaris10_hwmgr *data = (struct polaris10_hwmgr *)(hwmgr->backend);
|
|
|
uint16_t vv_id;
|
|
|
- uint16_t vddc = 0;
|
|
|
+ uint32_t vddc = 0;
|
|
|
uint16_t i, j;
|
|
|
uint32_t sclk = 0;
|
|
|
struct phm_ppt_v1_information *table_info =
|
|
@@ -2716,8 +2716,9 @@ static int polaris10_get_evv_voltages(struct pp_hwmgr *hwmgr)
|
|
|
continue);
|
|
|
|
|
|
|
|
|
- /* need to make sure vddc is less than 2v or else, it could burn the ASIC. */
|
|
|
- PP_ASSERT_WITH_CODE((vddc < 2000 && vddc != 0),
|
|
|
+ /* need to make sure vddc is less than 2v or else, it could burn the ASIC.
|
|
|
+ * real voltage level in unit of 0.01mv */
|
|
|
+ PP_ASSERT_WITH_CODE((vddc < 200000 && vddc != 0),
|
|
|
"Invalid VDDC value", result = -EINVAL;);
|
|
|
|
|
|
/* the voltage should not be zero nor equal to leakage ID */
|