@@ -347,13 +347,13 @@ static struct thermal_zone_device_ops imx_tz_ops = {
|
|
|
.set_trip_temp = imx_set_trip_temp,
|
|
|
};
|
|
|
|
|
|
-static int imx_init_calib(struct platform_device *pdev, u32 val)
|
|
|
+static int imx_init_calib(struct platform_device *pdev, u32 ocotp_ana1)
|
|
|
{
|
|
|
struct imx_thermal_data *data = platform_get_drvdata(pdev);
|
|
|
int t1, n1;
|
|
|
u64 temp64;
|
|
|
|
|
|
- if (val == 0 || val == ~0) {
|
|
|
+ if (ocotp_ana1 == 0 || ocotp_ana1 == ~0) {
|
|
|
dev_err(&pdev->dev, "invalid sensor calibration data\n");
|
|
|
return -EINVAL;
|
|
|
}
|
|
@@ -364,7 +364,7 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
|
|
|
* Use universal formula now and only need sensor value @ 25C
|
|
|
* slope = 0.4297157 - (0.0015976 * 25C fuse)
|
|
|
*/
|
|
|
- n1 = val >> 20;
|
|
|
+ n1 = ocotp_ana1 >> 20;
|
|
|
t1 = 25; /* t1 always 25C */
|
|
|
|
|
|
/*
|
|
@@ -392,12 +392,12 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
|
|
|
return 0;
|
|
|
}
|
|
|
|
|
|
-static void imx_init_temp_grade(struct platform_device *pdev, u32 val)
|
|
|
+static void imx_init_temp_grade(struct platform_device *pdev, u32 ocotp_mem0)
|
|
|
{
|
|
|
struct imx_thermal_data *data = platform_get_drvdata(pdev);
|
|
|
|
|
|
/* The maximum die temp is specified by the Temperature Grade */
|
|
|
- switch ((val >> 6) & 0x3) {
|
|
|
+ switch ((ocotp_mem0 >> 6) & 0x3) {
|
|
|
case 0: /* Commercial (0 to 95C) */
|
|
|
data->temp_grade = "Commercial";
|
|
|
data->temp_max = 95000;
|