Переглянути джерело

[S390] kernel: Fix dump on panic for DASDs under LPAR.

Currently the ccw method is used to ipl the DASD dump record under LPAR.
This mechanism is not reliable, which can cause dump failures. This fix
now uses the diag 308 ipl method for all machines, which have diag308
subcode 5 and 4 support.

Signed-off-by: Michael Holzheu <holzheu@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Michael Holzheu 18 роки тому
батько
коміт
e3d3683d14
1 змінених файлів з 2 додано та 0 видалено
  1. 2 0
      arch/s390/kernel/ipl.c

+ 2 - 0
arch/s390/kernel/ipl.c

@@ -648,6 +648,8 @@ static int dump_set_type(enum dump_type type)
 	case DUMP_TYPE_CCW:
 	case DUMP_TYPE_CCW:
 		if (MACHINE_IS_VM)
 		if (MACHINE_IS_VM)
 			dump_method = DUMP_METHOD_CCW_VM;
 			dump_method = DUMP_METHOD_CCW_VM;
+		else if (diag308_set_works)
+			dump_method = DUMP_METHOD_CCW_DIAG;
 		else
 		else
 			dump_method = DUMP_METHOD_CCW_CIO;
 			dump_method = DUMP_METHOD_CCW_CIO;
 		break;
 		break;