Browse Source

ab8500_fg: Don't clear the CCMuxOffset bit

The CCMuxOffset bit is not kept set. This will force the
columb counter of the AB8500 to use the measure offset
calibration. This should increase the accuracy of the fuel
gauge.

Signed-off-by: Kalle Komierowski <karl.komierowski@stericsson.com>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Kalle Komierowski 13 năm trước cách đây
mục cha
commit
e32ad07cea
1 tập tin đã thay đổi với 4 bổ sung4 xóa
  1. 4 4
      drivers/power/ab8500_fg.c

+ 4 - 4
drivers/power/ab8500_fg.c

@@ -484,8 +484,9 @@ static int ab8500_fg_coulomb_counter(struct ab8500_fg *di, bool enable)
 		di->flags.fg_enabled = true;
 	} else {
 		/* Clear any pending read requests */
-		ret = abx500_set_register_interruptible(di->dev,
-			AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG, 0);
+		ret = abx500_mask_and_set_register_interruptible(di->dev,
+			AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG,
+			(RESET_ACCU | READ_REQ), 0);
 		if (ret)
 			goto cc_err;
 
@@ -1403,8 +1404,7 @@ static void ab8500_fg_algorithm_discharging(struct ab8500_fg *di)
 		sleep_time = di->bat->fg_params->init_timer;
 
 		/* Discard the first [x] seconds */
-		if (di->init_cnt >
-			di->bat->fg_params->init_discard_time) {
+		if (di->init_cnt > di->bat->fg_params->init_discard_time) {
 			ab8500_fg_calc_cap_discharge_voltage(di, true);
 
 			ab8500_fg_check_capacity_limits(di, true);