@@ -1,29 +1,49 @@
|
|
|
-Representing flash partitions in devicetree
|
|
|
+Flash partitions in device tree
|
|
|
+===============================
|
|
|
|
|
|
-Partitions can be represented by sub-nodes of an mtd device. This can be used
|
|
|
+Flash devices can be partitioned into one or more functional ranges (e.g. "boot
|
|
|
+code", "nvram", "kernel").
|
|
|
+
|
|
|
+Different devices may be partitioned in a different ways. Some may use a fixed
|
|
|
+flash layout set at production time. Some may use on-flash table that describes
|
|
|
+the geometry and naming/purpose of each functional region. It is also possible
|
|
|
+to see these methods mixed.
|
|
|
+
|
|
|
+To assist system software in locating partitions, we allow describing which
|
|
|
+method is used for a given flash device. To describe the method there should be
|
|
|
+a subnode of the flash device that is named 'partitions'. It must have a
|
|
|
+'compatible' property, which is used to identify the method to use.
|
|
|
+
|
|
|
+We currently only document a binding for fixed layouts.
|
|
|
+
|
|
|
+
|
|
|
+Fixed Partitions
|
|
|
+================
|
|
|
+
|
|
|
+Partitions can be represented by sub-nodes of a flash device. This can be used
|
|
|
on platforms which have strong conventions about which portions of a flash are
|
|
|
used for what purposes, but which don't use an on-flash partition table such
|
|
|
as RedBoot.
|
|
|
|
|
|
-The partition table should be a subnode of the mtd node and should be named
|
|
|
+The partition table should be a subnode of the flash node and should be named
|
|
|
'partitions'. This node should have the following property:
|
|
|
- compatible : (required) must be "fixed-partitions"
|
|
|
Partitions are then defined in subnodes of the partitions node.
|
|
|
|
|
|
-For backwards compatibility partitions as direct subnodes of the mtd device are
|
|
|
+For backwards compatibility partitions as direct subnodes of the flash device are
|
|
|
supported. This use is discouraged.
|
|
|
NOTE: also for backwards compatibility, direct subnodes that have a compatible
|
|
|
string are not considered partitions, as they may be used for other bindings.
|
|
|
|
|
|
#address-cells & #size-cells must both be present in the partitions subnode of the
|
|
|
-mtd device. There are two valid values for both:
|
|
|
+flash device. There are two valid values for both:
|
|
|
<1>: for partitions that require a single 32-bit cell to represent their
|
|
|
size/address (aka the value is below 4 GiB)
|
|
|
<2>: for partitions that require two 32-bit cells to represent their
|
|
|
size/address (aka the value is 4 GiB or greater).
|
|
|
|
|
|
Required properties:
|
|
|
-- reg : The partition's offset and size within the mtd bank.
|
|
|
+- reg : The partition's offset and size within the flash
|
|
|
|
|
|
Optional properties:
|
|
|
- label : The label / name for this partition. If omitted, the label is taken
|