@@ -1198,7 +1198,7 @@ static int charger_extcon_notifier(struct notifier_block *self,
|
|
|
static int charger_extcon_init(struct charger_manager *cm,
|
|
|
struct charger_cable *cable)
|
|
|
{
|
|
|
- int ret = 0;
|
|
|
+ int ret;
|
|
|
|
|
|
/*
|
|
|
* Charger manager use Extcon framework to identify
|
|
@@ -1232,7 +1232,7 @@ static int charger_manager_register_extcon(struct charger_manager *cm)
|
|
|
{
|
|
|
struct charger_desc *desc = cm->desc;
|
|
|
struct charger_regulator *charger;
|
|
|
- int ret = 0;
|
|
|
+ int ret;
|
|
|
int i;
|
|
|
int j;
|
|
|
|
|
@@ -1255,15 +1255,14 @@ static int charger_manager_register_extcon(struct charger_manager *cm)
|
|
|
if (ret < 0) {
|
|
|
dev_err(cm->dev, "Cannot initialize charger(%s)\n",
|
|
|
charger->regulator_name);
|
|
|
- goto err;
|
|
|
+ return ret;
|
|
|
}
|
|
|
cable->charger = charger;
|
|
|
cable->cm = cm;
|
|
|
}
|
|
|
}
|
|
|
|
|
|
-err:
|
|
|
- return ret;
|
|
|
+ return 0;
|
|
|
}
|
|
|
|
|
|
/* help function of sysfs node to control charger(regulator) */
|
|
@@ -1372,7 +1371,7 @@ static int charger_manager_register_sysfs(struct charger_manager *cm)
|
|
|
int chargers_externally_control = 1;
|
|
|
char buf[11];
|
|
|
char *str;
|
|
|
- int ret = 0;
|
|
|
+ int ret;
|
|
|
int i;
|
|
|
|
|
|
/* Create sysfs entry to control charger(regulator) */
|
|
@@ -1382,10 +1381,9 @@ static int charger_manager_register_sysfs(struct charger_manager *cm)
|
|
|
snprintf(buf, 10, "charger.%d", i);
|
|
|
str = devm_kzalloc(cm->dev,
|
|
|
sizeof(char) * (strlen(buf) + 1), GFP_KERNEL);
|
|
|
- if (!str) {
|
|
|
- ret = -ENOMEM;
|
|
|
- goto err;
|
|
|
- }
|
|
|
+ if (!str)
|
|
|
+ return -ENOMEM;
|
|
|
+
|
|
|
strcpy(str, buf);
|
|
|
|
|
|
charger->attrs[0] = &charger->attr_name.attr;
|
|
@@ -1426,19 +1424,16 @@ static int charger_manager_register_sysfs(struct charger_manager *cm)
|
|
|
if (ret < 0) {
|
|
|
dev_err(cm->dev, "Cannot create sysfs entry of %s regulator\n",
|
|
|
charger->regulator_name);
|
|
|
- ret = -EINVAL;
|
|
|
- goto err;
|
|
|
+ return ret;
|
|
|
}
|
|
|
}
|
|
|
|
|
|
if (chargers_externally_control) {
|
|
|
dev_err(cm->dev, "Cannot register regulator because charger-manager must need at least one charger for charging battery\n");
|
|
|
- ret = -EINVAL;
|
|
|
- goto err;
|
|
|
+ return -EINVAL;
|
|
|
}
|
|
|
|
|
|
-err:
|
|
|
- return ret;
|
|
|
+ return 0;
|
|
|
}
|
|
|
|
|
|
static int cm_init_thermal_data(struct charger_manager *cm,
|
|
@@ -1626,7 +1621,7 @@ static int charger_manager_probe(struct platform_device *pdev)
|
|
|
{
|
|
|
struct charger_desc *desc = cm_get_drv_data(pdev);
|
|
|
struct charger_manager *cm;
|
|
|
- int ret = 0, i = 0;
|
|
|
+ int ret, i = 0;
|
|
|
int j = 0;
|
|
|
union power_supply_propval val;
|
|
|
struct power_supply *fuel_gauge;
|
|
@@ -1887,14 +1882,12 @@ MODULE_DEVICE_TABLE(platform, charger_manager_id);
|
|
|
|
|
|
static int cm_suspend_noirq(struct device *dev)
|
|
|
{
|
|
|
- int ret = 0;
|
|
|
-
|
|
|
if (device_may_wakeup(dev)) {
|
|
|
device_set_wakeup_capable(dev, false);
|
|
|
- ret = -EAGAIN;
|
|
|
+ return -EAGAIN;
|
|
|
}
|
|
|
|
|
|
- return ret;
|
|
|
+ return 0;
|
|
|
}
|
|
|
|
|
|
static bool cm_need_to_awake(void)
|