瀏覽代碼

charger-manager: Disable regulator when charger cable is detached

This patch disable regulator for charging when charger cable is detached
before stopping charging forcibly on abnormal battery state and check
return value of regulator_enable/disable() function to confirm correct
operation of enabling or disabling regulator for charging.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Chanwoo Choi 13 年之前
父節點
當前提交
dbb61fc745
共有 1 個文件被更改,包括 17 次插入2 次删除
  1. 17 2
      drivers/power/charger-manager.c

+ 17 - 2
drivers/power/charger-manager.c

@@ -271,9 +271,24 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
 	if (enable) {
 		if (cm->emergency_stop)
 			return -EAGAIN;
-		for (i = 0 ; i < desc->num_charger_regulators ; i++)
-			regulator_enable(desc->charger_regulators[i].consumer);
+		for (i = 0 ; i < desc->num_charger_regulators ; i++) {
+			err = regulator_enable(desc->charger_regulators[i].consumer);
+			if (err < 0) {
+				dev_warn(cm->dev,
+					"Cannot enable %s regulator\n",
+					desc->charger_regulators[i].regulator_name);
+			}
+		}
 	} else {
+		for (i = 0 ; i < desc->num_charger_regulators ; i++) {
+			err = regulator_disable(desc->charger_regulators[i].consumer);
+			if (err < 0) {
+				dev_warn(cm->dev,
+					"Cannot disable %s regulator\n",
+					desc->charger_regulators[i].regulator_name);
+			}
+		}
+
 		/*
 		 * Abnormal battery state - Stop charging forcibly,
 		 * even if charger was enabled at the other places