ソースを参照

[ARM] SMDK6410: Use active high IRQ for the WM8350 on the WM1190-EV1

Using an active high IRQ ensures that the WM8350 interrupt handling
does not spin when used with a SMDK6410 which has not had R20 removed
and R21 fitted to connect EINT12 to the PMIC module rather thant the
fixed regulators on the CPU module.

Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
Mark Brown 16 年 前
コミット
db9256f33c
1 ファイル変更1 行追加0 行削除
  1. 1 0
      arch/arm/mach-s3c6410/mach-smdk6410.c

+ 1 - 0
arch/arm/mach-s3c6410/mach-smdk6410.c

@@ -303,6 +303,7 @@ static int __init smdk6410_wm8350_init(struct wm8350 *wm8350)
 
 static struct wm8350_platform_data __initdata smdk6410_wm8350_pdata = {
 	.init = smdk6410_wm8350_init,
+	.irq_high = 1,
 };
 #endif